| SWITCH TIMERS | |||
|
Function:
switch electric |
|
|
|
| Standard features | MT - MTS 49 | MT - MTS 59 |
IT 51 - 52 - 53 - 54 ITS 55 - 56 - 57 |
|||
| 1. running times |
1' - 4' - 6' - 7' 10' - 15' - 20' - 30' |
30' - 45' - 60' 90' - 100' - 120' |
6' - 15' - 30' - 45' 60' - 90' - 120' - 180' |
|||
| 2. number of poles | on request: 1 or 2 poles | on request: 1 or 2 poles | on request: 1 or 2 poles | |||
| 3. OPTIONAL | switching wheel setting "continuously ON" or "continuously OFF" as desired | |||||
| 4. acoustic signal | Gong: optional | Gong: optional | Long Ring 2.5 sec: optional | |||
| 5. operating temperature | T 125ºC | T 125ºC | T 125ºC | |||
| 6. shaft diameter | 5-6-7 mm | 5-6-7 mm | 5-6-7 mm | |||
| 7. shaft length | on request | on request | on request | |||
| 8. shaft milling | on request | on request | on request | |||
| 9. shaft position | on request | on request | on request | |||
|
10. dimensions (mm) with acoustic signal |
40.5 x 51.5 x 45.6 | 43 x 58.5 x 52 |
ITS 55-56: diameter: 59 - thickness: 38.2ITS 57: diameter: 59 - thickness: 43.8
|
|||
|
11. dimensions (mm) without acoustic signal |
40.5 x 51.5 x 27.6 | 43 x 58.5 x 33.6 | IT: 51 x 56 x 38 | |||
| 12. life cycles | 10.000 | 10.000 | 10.000 | |||
| 13. AQL | 0,65 | 0,65 | 0,65 | |||
| 14. accuracy | ±10% | ±3% | ±3% | |||
| 15. load current |
16(3)A 250Vac T 125ºC ENEC 03 13(2)A 250Vac T 110ºC UL-CSA 15(2)A 120 Vac T 110ºC UL 15(4)A 120 Vac T 85ºC UL |
10(2)A 400Vac T 125ºC ENEC 03 16(3)A 250Vac T 125ºC ENEC 03 13(2)A 250Vac T 110ºC UL-CSA 15(2)A 120 Vac T 110ºC UL 15(4)A 120 Vac T 85ºC UL |
16(3)A 250Vac T 125ºC ENEC 03 IT 16(1/4 hp)A UL |
|||
| 16. conformity with | EN 60730-2-1 | EN 60730-2-1 | EN 60730-2-1 | |||
| 17. APPROVALS | ENEC 03 - UL - CSA | ENEC 03 - UL - CSA | ENEC 03 - UL | |||
| CUSTOMIZED PRODUCTS AVAILABLE ON REQUEST | ||||||