Standard features
|
 |
MT - MTS 49
|
 |
MT - MTS 59
|
 |
IT 54
|
 |
|
1. running times
|
 |
1' - 4' - 6' - 7' - 10' - 15' - 20' - 30'
|
 |
30' - 45' - 60' - 90' - 100' - 120'
|
 |
6' - 15' - 30' - 60' - 90' - 120' - 180'
|
 |
|
2. number of poles
|
 |
2 poles advanced opening
|
 |
2 poles advanced opening
|
 |
2 poles advanced opening
|
 |
|
3. OPTIONAL
|
 |
switching wheel setting "continuously ON" or "continuously OFF" as desired
|
 |
|
4. acoustic signal
|
 |
Gong: optional
|
 |
Gong: optional
|
 |
|
 |
|
5. operating temperature
|
 |
T 125ºC
|
 |
T 125ºC
|
 |
T 125ºC
|
 |
|
6. shaft diameter
|
 |
5-6-7 mm
|
 |
5-6-7 mm
|
 |
5-6-7 mm
|
 |
|
7. shaft length
|
 |
on request
|
 |
on request
|
 |
on request
|
 |
|
8. shaft milling
|
 |
on request
|
 |
on request
|
 |
on request
|
 |
|
9. shaft position
|
 |
on request
|
 |
on request
|
 |
on request
|
 |
10. dimensions (mm)
with acoustic signal
|
 |
40.5 x 51.5 x 45.6
|
 |
43 x 58.5 x 52
|
 |
|
 |
11. dimensions (mm)
without acoustic signal
|
 |
40.5 x 51.5 x 27.6
|
 |
43 x 58.5 x 33.6
|
 |
51 x 56 x 38
|
 |
|
12. life cycles
|
 |
10.000
|
 |
10.000
|
 |
10.000
|
 |
|
13. AQL
|
 |
0,65
|
 |
0,65
|
 |
0,65
|
 |
|
14. accuracy
|
 |
±10%
|
 |
±3%
|
 |
±3%
|
 |
|
15. load current
|
 |
16(3)A 250Vac T 125ºC ENEC 03

13(2)A 250Vac T 110ºC UL-CSA

15(2)A 120 Vac T 110ºC UL

15(4)A 120 Vac T 85ºC UL
|
 |
10(2)A 400Vac T 125ºC ENEC 03

16(3)A 250Vac T 125ºC ENEC 03

13(2)A 250Vac T 110ºC UL-CSA

15(2)A 120 Vac T 110ºC UL

15(4)A 120 Vac T 85ºC UL
|
 |

16(3)A 250Vac T 125ºC ENEC 03


IT (1/4 hp)120-240 Vac


|
 |
|
16. conformity with
|
 |
EN 60730-2-1
|
 |
EN 60730-2-1
|
 |
EN 60730-2-1
|
 |
|
17. APPROVALS
|
 |
ENEC 03 - UL - CSA
|
 |
ENEC 03 - UL - CSA
|
 |
ENEC 03 - UL
|
 |
|